| 1 | Three-Phase SCR Rectifier | Controlled silicon rectifier bridge with phase-angle control | 380–480 V AC, 3-phase | 6–24 V DC 500–10,000 A | 80–92% | 4–8% | Standard feature; trips or limits firing when an input phase is missing | Air or water cooled | General-purpose hard chrome and decorative chrome lines requiring high current |
| 2 | Three-Phase IGBT Switch-Mode Rectifier | High-frequency insulated-gate bipolar transistor inverter and transformer | 380–480 V AC, 3-phase | 6–24 V DC 100–5,000 A | 88–96% | Below 1–3% | Fast electronic detection with shutdown, alarm, and restart interlock | Forced-air or liquid cooled | Precision chrome deposits, automated lines, and energy-conscious installations |
| 3 | 12-Pulse SCR Rectifier | Two six-pulse bridges supplied through a phase-shifting transformer | 380–690 V AC, 3-phase | 6–24 V DC 1,000–20,000 A | 82–93% | 1–3% | Phase monitoring on the primary input and controlled-current fallback | Oil, air, or water cooled | Large chrome tanks where lower ripple and reduced harmonic distortion are important |
| 4 | Diode Bridge Transformer Rectifier | Three-phase transformer followed by an uncontrolled diode bridge | 380–480 V AC, 3-phase | 6–18 V DC 300–5,000 A | 85–94% | 5–10% | Input relay, fuse, or monitoring circuit disconnects the unit during phase loss | Natural or forced-air cooled | Fixed-current or fixed-voltage applications with simple operating requirements |
| 5 | Pulsed-DC Chrome Rectifier | Electronic switching circuit producing programmable current pulses | 380–480 V AC, 3-phase | 0–20 V DC 100–3,000 A | 85–95% | Below 1–3% during each pulse | Digital phase-loss alarm, gate inhibition, and controlled shutdown | Forced-air or liquid cooled | Applications needing control of deposit structure, coverage, or current distribution |
| 6 | Reversing-Polarity Chrome Rectifier | Controlled DC output with automatic forward and reverse current cycles | 380–480 V AC, 3-phase | ±6–24 V DC 100–5,000 A | 82–94% | 1–5% | Phase-loss monitoring combined with zero-crossing protection before polarity change | Air or water cooled | Chrome plating and electrochemical preparation processes using periodic reverse current |
| 7 | Modular Parallel Rectifier | Multiple independently monitored power modules connected in parallel | 380–480 V AC, 3-phase | 6–24 V DC 500–10,000 A | 88–96% | Below 1–4% | Each module monitors phase condition and can isolate itself from the DC bus | Forced-air or liquid cooled | Expandable production lines requiring serviceability and partial-load operation |
| 8 | Water-Cooled High-Current Rectifier | SCR or IGBT power stage with liquid-cooled semiconductor assemblies | 380–690 V AC, 3-phase | 6–24 V DC 2,000–30,000 A | 85–95% | 1–6% | Phase-loss trip combined with coolant-flow, temperature, and leakage protection | Closed-loop or plant-water cooled | Large hard-chrome tanks and continuous high-current production |
| 9 | Air-Cooled Compact Chrome Rectifier | Compact SCR or high-frequency switching power stage | 220–480 V AC | 6–24 V DC 50–1,000 A | 82–94% | 2–8% | Input phase relay or digital monitor provides alarm and output shutdown | Natural or forced-air cooled | Small tanks, laboratory work, maintenance plating, and low-to-medium current loads |
| 10 | PLC-Integrated Smart Rectifier | SCR or IGBT power stage with digital control and industrial communication | 380–480 V AC, 3-phase | 0–24 V DC 100–10,000 A | 84–96% | Below 1–6% | Real-time phase-loss, phase-sequence, undervoltage, and overtemperature diagnostics | Air or water cooled | Automated chrome-plating systems requiring recipe control, data logging, and remote status monitoring |